Multi-Channel Image Transmission (Network Transmission) Data Link
Product profile and purpose
This measurement and control data link system includes airborne mobile equipment and fixed equipment on the ground. It is used to establish wireless link between the airborne mobile equipment in the air and the fixed equipment on the ground, and make real-time display of the dual-channel image on display screen of the fixed equipment on the ground. The fixed equipment on the ground sends dual-channel bi-directional RS-422 signal, connects to on-board equipment, and is used to control their respective servo gear. In the meantime, it provides one-channel stable bi-directional headset call. Both the airborne mobile equipment and the fixed equipment on the ground are equipped with independent power supply and backup power supply for long operating hours.
Site demonstration
Main characteristics
Dual-channel image downward transmission, dual-channel bi-directional RS-422 signal, baud rate of 230400bps, and one-channel bi-directional headset call. Both the airborne equipment and the ground equipment are equipped with independent power supply and backup power supply, and the ground equipment has two 10-inch display screens, which can enable real-time and convenient view of the images.
Technical indicators
Operating distance | ≥ 40 km (under the condition of guaranteeing visual distance) | Telemetry data rate | ≥ 125kbps |
Bit error rate of data | < 1×10-6 | ||
Operating frequency range | 340MHz~580MHz | Data delay | ≤ 50ms |
Image transmission rate | ≥ 4Mbps | Image delay | ≤ 400ms |
Site demonstration
Airborne equipment | Ground equipment | |
Dimension of equipment | This equipment is a customized one, and its dimension can be designed according to customer requirements | Portable case |
Weight | ≤ 8.0Kg | ≤ 20.0Kg |
Power consumption | ≤ 170W | ≤ 170W |
Power supply | DC28V±3V (equipped with battery pack that can make power supply for above 6 hours) | DC28V±3V or AC220V (equipped with battery pack that can make power supply for above 6 hours) |
Data interface | 2-channel RS422 interface, RJ45 Ethernet port | 2-channel RS422 interface, RJ45 Ethernet port |
Image interface | Dual-channel PAL interface | Dual-channel PAL interface |
Image interface | Dual-channel PAL interface | One-channel voice interface |
Operating temperature | -40℃ ~ 60℃ | -40℃ ~ 60℃ |
Physical product